TOA Electronics NX-100S Network Cables User Manual


 
3-26
Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)
Step 5. Set the type to [Momentary] or [Latch].
Momentary: Provides output during the period between receiving an activation request and receiving
a stop request.
Latch: Provides 1 second of output upon receiving an activation request and 1 second of output
upon receiving a stop request.
Note
[Latch] cannot be selected when setting Mode to [STATUS Output] or [ERROR Output].
1 s
1 s
Broadcast and
activation data
Contact output
Contact output
Make
Break
• Latch
Broadcast and
activation data
Contact output
Contact output
Make
Break
• Momentary
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Activation Stop
Activation Stop
Caution
The unit's correct operation cannot be ensured if both activation and stop signals
are received during the 1-second output interval.
Step 6. Select Polarity from [Make] or [Break].
Make: ON when the contact is closed.
Break: ON when the contact is opened.
Step 7. Set OFF delay time from [0] – [60] seconds.
Adjust the displayed scale or enter an OFF delay time of 0 – 60 seconds for the duration between
receiving a termination request and actually turning OFF the contact. When in Resend mode (refer to
p. 3-19, Packet loss recovery) and making broadcasts with longer delay times, set the OFF delay time
to correspond to the delay time.
Note
For more information regarding OFF delay times, refer to p. 6-4.