Toshiba 5520c All in One Printer User Manual


 
e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reserved
2-39
2. Copier-specific Adjustments
(2) Press the [IMAGE] button on the Control Panel. Press the [SHARPNESS] button.
Press the [SOFT] button to soften the copy image.
After softening the copy image, copy and check the copy image quality.
If further image quality adjustments is necessary, go to the next step.
(3) Enter adjustment mode [05].Change the values for codes [604] to [606], [922], [1737] to [1741], [1757],
[7795] and [7807] to [7809] to adjust the default value for the sharpness intensity.
* Decreasing the sharpness intensity will minimize moiré.
Color mode Original mode [05] code
Recommended
value
Accepta
ble value
range
Default
Text / Photo 05-604
Text 05-605
Photo 05-606
User custom 05-922
Black
Image smoothing 05-7809
Set a value smaller
than 128.
28 to 127
0 to 255 128
Text / Photo 05-1737
Text 05-1738
Printed image 05-1739
Photo 05-1740
Map 05-1741
Full color
User custom 05-7795
Set a value smaller
than 128.
28 to 127
0 to 255 128
Text / Photo 05-1757
Text 05-7807
ACS / Black
Photo 05-7808
Set a value smaller
than 128.
28 to 127
0 to 255 128
* The smaller the value is, the weaker the sharpness intensity becomes. The larger the setting value is, the
stronger the sharpness intensity becomes.
Changing the values for these codes will change the sharpness intensity, when the "Sharpness" indicator in
the "IMAGE" menu is set to the center. Remember that 1 step of the indicator will increase or decrease the
sharpness intensity by 25. If the sharpness intensity of the center value is changed, each step of the
indicator will be changed accordingly. (For instance, if the center value is decreased by 25 (softer), the
value of each step of the indicator will also be decreased by 25 (softer).)
However, the range of adjustment values that is valid for sharpness level change is from -100 to +100 of
the total of the setting value of the adjustment code and that of the indicator. For instance, if the setting
value of the adjustment code is "103" (-25 from the default value), the limit of the steps in the soft side of
the indicator is "-3". If the step is set at "-4", the image quality will not be changed.