Toshiba B-SA4TP SERIES Printer User Manual


 
2. PRINTER SETUP
ENGLISH VERSION EO1-33048
2.7 Setting an Operating Environment
E2-20
2.7.2 Parameter Setting
(Cont.)
Serial (RS-232C) Interface
(2) Data Length
This parameter is to choose a data length of the RS-232C interface.
As “8 bits” has been chosen as default, change it in accordance with your
PC.
After making a choice, press the [PAUSE] key.
(3) Stop Bit
This parameter is to choose a stop bit of the RS-232C interface.
As “1 bit” has been chosen as default, change it in accordance with your
PC.
After making a choice, press the [PAUSE] key.
(4) Parity
This parameter is to choose a parity of the RS-232C interface.
As “None” has been chosen as default, change it in accordance with your
PC.
After making a choice, press the [PAUSE] key.
<2>PARAMETER SET
PARITY NONE
PARITY EVEN
PARITY ODD
[RESTART]
[FEED]
PARITY NONE
<2>PARAMETER SET
DATA LENG. 8bits
DATA LENG. 8bits
DATA LENG. 7bits
[RESTART]
[FEED]
<2>PARAMETER SET
STOP BIT 1bit
STOP BIT 1bit
STOP BIT 2bits
[RESTART]
[FEED]