Toshiba B-SA4TP SERIES Printer User Manual


 
APPENDIX 1 MESSAGES AND LEDS
ENGLISH VERSION EO1-33048
APPENDIX 1 MESSAGES AND LEDS
EA1- 2
LED Indicatio
n
No.
LCD Message
ONLINE ERROR
Printer Status
Restoration by
RESTART ke
y
(Yes/No)
Acceptance of
Status Request
Reset Command
(Yes/No)
21 SYSTEM ERROR z
When the following abnormal operations are
performed, a system error occurs:
(a) Command fetch from an odd address
(b) Access to word data at an odd address
(c) Access to long-word data at an odd
address
(d) Access to the area of 80000000H to
FFFFFFFFH in the logic space in user
mode.
(e) An undefined instruction in an area
other than a delay slot was decoded.
(f) An undefined instruction in a delay slot
was decoded.
(g) An instruction to rewrite a delay slot
was decoded.
No No
22
100BASE LAN
INITIALIZING…
z z
100 Base LAN Board is being initialised. ----- -----
23
DHCP CLIENT
INITIALIZING…
z z
The DHCP client is being initialized.
*When the DHCP function is enabled.
----- -----
24 RFID WRITE ERROR z
The printer did not succeed in writing data
onto an RFID tag after having retried for a
specified times.
Yes Yes
25 RFID ERROR z
The printer cannot communicate with the
RFID module.
Yes Yes
NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5