Toshiba SATEGO L300D Laptop User Manual


 
4.5MDCModule 4ReplacementProcedures
SatelliteL300D/L305D/SatelliteProL300D/EQUIUML300D/SATEGOL300D
MaintenanceManual
4-25
InstallingtheMDCModule
InstalltheMDCmoduleaccordingtothefollowingproceduresandFigures4-10,after
checkingthatthecomputeristurnedoffinbootmode.
CAUTION:InstalltheMDCmoduleafterturningoffthecomputer.Ifthisisviolated,
thecomputerorMDCmodulecanbedamaged.
CAUTION:DonottouchtheconnectorsontheMDCmoduleorinthecomputer.
ContaminatedconnectorscancauseMDCmodulefailures.
1. ConnecttheMDCcabletoconnectorJ1ontheMDCmodule.
2. ConnecttheMDCmoduletoCN6onthesystemboard.
3. SecuretheMDCmodulewithtwoM2x3blackflatheadscrews.
Note:Afterthecomputeristurnedon,checkthehardwareconfigurationintheHardware
SetuporTSETUPprogramtomakesurethattheinstalledMDCmodulehasbeenrecognized
bythesystem.Ifithasnotbeenrecognizedyet,checktheconnections.