Toshiba SATELLITE PRO A120 Personal Computer User Manual


 
1.7 Batteries 1 Hardware Overview
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573) [CONFIDENTIAL] 1-29
Charge is stopped in the following cases.
1. The main battery is fully charged.
2. The main battery is removed.
3. Main battery or AC adapter voltage is abnormal.
4. Charging current is abnormal.
Data preservation time
When turning off the power in being charged fully, the preservation time is as following
Table 1-11.
Table 1-11 Data preservation time
Battery type Standby mode Boot mode
Main battery (3,600 mAh) 5 days 65 days
Main battery (4,700 mAh) 6 days 80 days
1.7.2 RTC battery
The RTC battery provides power to keep the current date, time and other setup information
in memory while the computer is turned off. Table 1-12 lists the charging time and data
preservation period of the RTC battery.
Table 1-12 RTC battery charging/data preservation time
Status Time
Charging Time (power on) 8 hours
Data preservation period (full charge) 30 days