Toshiba TLP-ET1U Projector User Manual


 
Maintenance
44
Reset the lamp timer.
q Turn on the power of this unit.
The startup screen appears, followed by the replacement message screen.
w Press the MENU button.
The menu screen appears.
e Select Lamp time reset in the Default setting menu and press the OK button.
r Select Yes on the dialog screen, then press the OK button.
The lamp time is reset.
PRECAUTIONS
Take Step 9 above within seven minutes after turning on the power.
Be sure to reset the lamp time after replacing the lamp.
The lamp may burst if you continue to use it without replacing while resetting the lamp time.
Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the lamp will not come on
(see
p.45).
Always replace the lamp with a new one.
The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it.
(Dirt, jolts, scratches and the like could break the lamp.)
Used lamps
This projectors lamps contain trace amounts of environmentally harmful inorganic mercury. Be
careful not to break used lamps, and dispose it in accordance with local regulations.
Lamp replacement (Continued)