TL-SL3428/TL-SL3452 JetStream L2 Managed Switch CLI Guide
196
spanning-tree —— Enable spanning-tree trap. It is sent when the port forwarding
status changes or the port receives TCN packet or packet with TC flag.
memory —— Enable memory trap. It is sent when CPU usage exceeds 80%.
Command Mode
Global Configuration Mode
Example
Enable SNMP extended bandwidth-control trap for the switch:
TL-SL3428(config)# snmp-server traps bandwidth-control
snmp-server traps mac
Description
The snmp-server traps mac command is used to enable SNMP extended
MAC address-related traps which include four types: new, full,
learn-mode-change and max-learned. To disable the sending of SNMP
extended MAC address related traps, please use no snmp-server traps mac
command.
Syntax
snmp-server traps mac [ new | full | learn-mode-change | max-learned ]
no snmp-server traps mac [ new | full | learn-mode-change | max-learned ]
Parameter
new —— Enable new MAC address trap. It is sent when the switch learns new
MAC address including dynamic address, static address and filter address.
full —— Enable MAC address table trap. It is sent when the MAC address table
is full.
learn-mode-change —— Enable MAC address learn-mode-change trap. It is
sent when MAC address learning mode of the switch changes.
max-learned —— Enable MAC address max-learned trap. It is sent when the
amount of learned MAC address reaches the limit which is configured in port
security module.
Command Mode
Global Configuration Mode