Tyco 0-1591099-x Switch User Manual


 
24 Port Stackable Managed Switch – User Guide Page 21
Port Flow Control (FC)
This allows a full-duplex port to negotiate with connected equipment to implement a flow
control process using embedded Pause frames. The default setting is ON.
Back Pressure (BP)
This allows a half-duplex port to use back pressure as a method of flow control. The default
is OFF.
Bandwidth In/Out
Limits a port transmit and receive bandwidth. The bandwidth limiting can be configured
between 0 - 999 in 100Kbps increments. The default is 0, which is no rate limiting.
Priority
Configures a port to be high or low priority. Packets entering this port will be assigned a
priority and will follow the rule as defined in the Priority Configuration menu. The default is
Disable.
Security
Stops a port from learning new MAC addresses, which is useful when security is needed to
disallow an unauthorized connection to the port. This can be used in conjunction with Static
MAC Address Configuration to allow only a known and authorized MAC address to use this
port. The default is OFF.
Product Number 0-1591099-x © Tyco Electronics 2005 Issue 1