Chapter 2
31
Barcode Symbologies
Note: *Value Adjustable Scanner Control Panel V3.0
Symbology Enable/
Disable
Check
Char/Digit
verification
Transmit
Check
Char/digit
Max/
Min
Length
Transmit
Leading
Digit
Other
Bookland EAN YES — — — — —
Codabar YES YES YES — — Transmit Start/Stop
bits, CLSI format,
*data length
Code 11 YES — YES — — * check digits, *data
length
Code 128 YES — — — — *data length
Code 32 YES — — — YES Transmit Tailing digit
Code 39 YES YES — — — For ASCII, Transmit
Start/Stop bits,
Function Code,
Double label
decoding, *data
length, *double labels
separator
Code 93 YES — Yes — — *data length
Deta Code YES YES YES — — —
EAN 128 YES — Yes — — Transmit Code ID,
* Field separator
EAN 13 YES YES — — YES —
EAN 8 YES YES — — YES * Not suppress first or
last digit, *data length
Interleaved 2 of
5
YES YES YES — — Fixed Length, * Not
suppress first or last
digit, *data length
Label Code
IV&V
YES — YES — — —
MSI/Plessey YES — YES — — * Check digit double
module 10, * data
length
Standard 2
of 5
YES YES YES — — Fixed Length, *Data
Length
Telpen YES — — — — *Standard
Character Set
UPC A YES — YES — YES
UPC E YES — YES — YES Zero Expansion,
NSC
UPC/EAN
Group
— — — — — Supplement 2,
Supplement 5,Insert
Space before
supplement, most
have supplement,
*Add-on code try
level