Vidikron v120 Projector User Manual


 
Operation
58 Vidikron Vision Model 120 Owner’s Operating Manual
PRE
L
IMINAR
Y
Overscan: Image Overscan pushes the outside edge of the active picture area of the video
signal out beyond the edge of the display area.
Some television programs are produced based on the assumption that older television sets
may not display the outer edges of the broadcast picture area. Over scan effectively trims
away these inactive, outer edges and enlarges the remaining portion of the image to fill the
display area.
Select from 1% to 10% of Overscan, as desired.
For HDTV, DVDs and other video sources, Overscan is generally not necessary or desirable.
Phase: Adjust the phase if the image from an RGB or Component source shows shimmer or
“noise.” Pixel phase adjusts the phase of the pixel sampling clock relative to the incoming
signal. The effect of this control is similar to that of a tracking control on a VCR.
For best results, use a good test pattern such as a smooth gray consisting of a clear pattern of
black and white pixels, or a similar “half on, half off” graphic image. (You may find that you
can stabilize the image at more than one point. Use either setting in this case.)
ISF Presets For each input, the Vision 120 lets you save image quality settings as presets that you can
recall at a later time. You can create up to four presets per input and resolution. Use the ISF
Presets menu to recall saved image presets, or to save image settings in the “Custom
1” or
“Custom
2” memory location. The currently-selected preset is indicated by a “7” to its left; in
the example shown here, ISF Night is selected.
You should save changes to any of the following settings to a preset; otherwise they will be
lost when a new input source or resolution is selected:
•Brightness
Contrast
Color saturation
•Tint
Sharpness
To reset the Custom 1 and Custom 2 image presets to their factory defaults, select Factory
Default and press ENTER or SELECT.
Information Select Information from the Main Menu to display information about the current input signal
(resolution, frequency, type et cetera) and installed firmware versions. Should you ever need
to contact Vidikron Technical Support, this information will help them answer your questions
or resolve product performance issues.
ISF Presets
7
ISF Night
ISF Day
Custom 1 Save
Custom 2 Save
Factory Default
Information
Resolution 1280x768@60
CB Firmware 0.31 (T23)
CB FPGA rxrev018.sxf
SB Firmware 0.42M1
SB FPGA 0.25
Scaler 2.0
OSD E019