Western Telematic IPS-800-D20, IPS-800E-D20, IPS-1600-D20, IPS-1600E-D20 Switch User Manual


 
6-5
Operation
To Switch Plugs, or initiate a Boot Cycle, proceed as follows:
1. Switch Plug(s) On: To power-on a plug, type /ON n and press [Enter].
Where "n" is the number or name of the desired plug.
For example:
/ON 1 or /ON ROUTER
2. Switch Plug(s) Off: To power-off a plug, type /OFF n and press
[Enter]. Where "n" is the number or name of the desired plug. Note that
the "/OFF" command can also be entered as "/OF". For example:
/OFF 2 or /OF ROUTER
3. Boot Plug(s): To initiate a Boot cycle, type /BOOT n and press [Enter].
Where "n" is a the number or name of the desired plug. Note that the
"/BOOT" command can also be entered as "/BO". For example:
/BOOT 1 or /BO ATMSWTCH
4. Set Plugs to Power Up Defaults: Type /D and press [Enter]. Plugs
will be set to their default On/Off status, which is defined using the Plug
Parameters Menu as described in Section 5.3.3.
Notes:
When you have accessed command mode using the System
Password, the Default command will be applied to all plugs.
When you have accessed command mode using a Plug (User)
Password, the Default command will only be applied to the plugs
permitted by the password.
5. Suppress Command Confirmation Prompt: To execute a Boot/On/Off
command without displaying the "Sure?" prompt, include the ",Y" option
at the end of the command line. For example:
/ON ROUTER,Y or /BOOT 2,Y