Western Telematic RPC-4840N Network Card User Manual


 
To enable/disable the Automated Mode, access the RPC-4840N
General Parameters menu, and proceed as described in
Section 5.4. When the Automated Mode is enabled, RPC
functions will change as follows:
1. All Password Security Suppressed: When a user
attempts to access the command mode, the password
prompt will not be displayed at either the Network Port,
Modem Port, or Console Port. Unless restricted by the IP
Security Function, all users will be allowed to access
System Level command functions and control both
circuits. At the Console Port, all commands are
immediately accepted, whether the circuit is awake
or asleep.
2. Status Screen Suppressed: The status screen will not be
automatically displayed after commands are successfully
executed. Note however, that the /S command can still be
invoked to display the status screen if desired.
3. "Sure?" Prompt Suppressed: All commands are
executed without prompting for user confirmation.
4. Error Messages Suppressed: If the [Enter] key is
pressed without entering a command, the RPC will not
respond with the "Invalid Command" message. Note
however, that an error message will still be generated if
commands are invoked using invalid formats or arguments.
All other status display and configuration commands will still
function as normal.