Xantrex Technology GPIB-M-XT Power Supply User Manual


 
108 Operating Manual for Multichannel Functionality (GPIB-M)
SCPI Command Reference
SCPI Command Summary
Table B.7Commands for Fold Protection
Table B.8Commands for Triggering
Table B.9System Commands
Function
SCPI Command
Description Query
Set Output Fold Delay
[:]OUTPut[<channel>]:PROTection:FOLD:DELay <delay>
Set the delay time (seconds) before fold
protection is triggered.
Yes
Set Output Fold Mode
[:]OUTPut[<channel>]:PROTection:FOLD[:MODE]
{NONE|CC|CV}
Select which regulation mode to fold back
(None,CV, CC, CP)
Yes
Query Fold Protection
Tripped
[:]OUTPut[<channel>]:PROTection:FOLD:TRIPped?
Query if fold protection has tripped
N/A
Function
SCPI Command
Description Query
Set Immediate Initiation of
Trigger System
[:]INITiate[<channel>][:IMMediate]
Initiate a triggered event or sequence N/A
Set Trigger Source
[:]TRIGger[<channel>][:SEQuence]:SOURce
{BUS|EXTernal|IMMediate|NONE}
Sets the trigger source for triggered
setpoints
Yes
Function
SCPI Command
Description Query
Query System Error
[:]SYSTem[<channel>]:ERRor[:NEXT]?
Returns the next error in the instrument’s
error queue
N/A
Recall Default Factory
Preset
[:]SYSTem[<channel>]:RECall:DEFault
Restore the factory preset values N/A
Select Remote Control
Source
[:]SYSTem[<channel>]:REMote:SOURce {GPIB|MCHannel}
Change the remote control source Yes
Set Multichannel Address
[:]SYSTem[<channel>]:COMMunicate:MCHannel:ADDRess
<channel>
Select the multichannel unit address Yes
Set GPIB Address
[:]SYSTem[<channel>]:COMMunicate:GPIB[:SELF]:ADDRess
<GPIB_address>
Configure GPIB address Yes
Set GPIB Power On
Service Request
[:]SYSTem[<channel>]:COMMunicate:GPIB[:SELF]:PONSrq
{ON|OFF|0|1}
Configure GPIB PON SRQ Yes
Set Remote Control
Operation (Serial
Interface)
[:]SYSTem[<channel>]:REMote:STATe
{LOCal|REMote|RWLock}
RS-232 Only. Change remote control mode Yes
Query SCPI Version
[:]SYSTem[<channel>]:VERSion?
Returns the SCPI version to which the
instrument complies. Format is YYYY.V
N/A