Features and Specifications
Specifications
Release 2.1 23
Table 1.5 Specifications for XPD 500 W with GPIB-M or CANbus
Table 1.6 Specifications for XT 60 W with GPIB-M or CANbus
Models 7.5-67 18-30 33-16 60-9 120-4.5
Program Resolution
Voltage
Current
1.2mV
5.2mA
4.6mV
3.6mA
5.1mV
2.9mA
9.3mV
1.3mA
18.6mV
0.7mA
Program Accuracy
1
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XPD 18-30 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
10mV
±0.12%
250mA
±0.1%
75mV
±0.12%
140mA
±0.1%
75mV
±0.12%
115mA
±0.15%
150mV
±0.3%
80mA
±0.15%
180mV
±0.25%
80mA
±0.1%
Readback Resolution
Voltage
Current
1.2mV
5.2mA
4.6mV
3.6mA
5.1mV
2.4mA
9.3mV
1.3mA
18.6mV
0.7mA
Readback Accuracy
1
Voltage
Current
30mV
±0.12%
250mA
±0.1%
75mV
±0.12%
140mA
±0.1%
75mV
±0.2%
115mA
±0.15%
150mV
±0.3%
80mA
±0.15%
180mV
±0.25%
80mA
±0.1%
Models 7-6 15-4 20-3 30-2 60-1 120-0.5 250-0.25
Program Resolution
Voltage
Current
1.1mV
1.0mA
2.4mV
0.6mA
3.1mV
0.5mA
4.7mV
0.3mA
9.3mV
0.2mA
17mV
0.1mA
17mV
0.1mA
Program Accuracy
1
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XT 15-4 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 20mV ± 0.1% of the set voltage of 10 volts.
10mV
±0.1%
110mA
±0.15%
20mV
±0.1%
70mA
±0.15%
20mV
±0.15%
50mA
±0.15%
30mV
±0.15%
40mA
±0.15%
200mV
±0.15%
26mA
±0.2%
400mV
±0.15%
13mA
±0.2%
400mV
±0.15%
13mA
±0.2%
Readback Resolution
Voltage
Current
1.1mV
1.0mA
2.4mV
0.6mA
3.1mV
0.5mA
4.7mV
0.3mA
9.3mV
0.2mA
17mV
0.1mA
17mV
0.1mA
Readback Accuracy
1
Voltage
Current
10mV
±0.15%
110mA
±0.15%
10mV
±0.1%
70mA
±0.15%
10mV
±0.1%
50mA
±0.15%
15mV
±0.1%
40mA
±0.15%
35mV
±0.15%
26mA
±0.2%
70mV
±0.15%
13mA
±0.2%
70mV
±0.15%
13mA
±0.2%