Xantrex Technology 400 Plus, 400 R Power Supply User Manual


 
Troubleshooting
5-4 975-0162-01-01
Run time is
less than
expected.
Internal battery is not
fully charged.
AC appliance power
consumption is higher
than expected.
Recharge using the AC Charger,
until green Charging Status light is
steady.
Check AC appliance power or
wattage rating (or current draw for
12 V dc appliances) and compare
with Table 3-1 on page 3–11 and
Table 3-2 on page 3–14.
For additional information on
battery run times, see the Battery
App Note under the Support Section
at www.xantrex.com.
Charging
Status light is
OFF when AC
Charger is
connected
No AC power at the
AC wall outlet.
AC Charger is faulty.
Ensure power is available at the AC
wall outlet.
Replace the AC Charger.
Green
Charging
Status light is
flashing
(indicating
recharging)
and Battery
Charge (%)
does not turn
on.
Battery Charge (%)
reading on digital
display is only
accurate when the
XPower Powerpack
has been disconnected
from all appliances
and all charging
sources for fifteen
minutes.
Unplug the charging sources and any
appliances and let the XPower
Powerpack rest for 15 minutes to
obtain an accurate reading.
The
compressor
runs slowly.
The compressor may
have overheated from
excessive use.
Battery voltage is too
low.
Turn off the compressor and let it
cool down.
Check the condition of the internal
battery. The battery may need to be
recharged or replaced.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution
975-0162-01-01_Rev-C.book Page 4 Friday, October 20, 2006 10:40 AM