COAX COMMUNICATIONS BUFFER
Table D-3. Control unit output area (continued)
Address Function Description
X'0017'
(cont.)
DSC Query
Load Translate
Table
Load Structured
Field
bits 0—7
Bits 0—7
Bits 0—7
Ignored
Ignored
Ignored
X'0018' Maximum Print
Position
This byte specifies the maximum print position
for 3270 DSC mode. If zero, the value defined
at the printer control panel is used.
X'0019'
to
X'0021'
Reserved
X'0022' Extended Order
Bit 0
Bit 1
Bit 2
Bit 3—7
For extended order byte 0017, bit 0 must
equal 1.
Reserved
0—Continue on error. Any SCS control
code not supported prints a hyphen,
but does not return an error response.
1—Stop on error. Any SCS control code not
supported returns a “function not
supported” response to the control unit
and printing stops.
Ignored
Reserved
X'0023'
to
X'0049'
Reserved
X'004A'
to
X'004D'
Test
Message
Test message from control unit:
AA 32 87 AA (for 3274/3287)
AA 32 62 AA (for 3276/3262)
X'004E'
X'004F'
Reserved