Xerox 4230/MRP All in One Printer User Manual


 
FUNCTION SELECTION VIA LINE (FSL) COMMANDS
Example @Y4, 2@ sets the protocol converter to double space default.
Y5—Set Default Maximum Page Length (MPL)
@Y5,n@
Selects current and default form length. It selects the power up
default value for the Maximum Page Length (MPL) in units of
single line spaces.
n Valid parameters are:
000—255 Indicates the maximum number of
lines allowed on a page before a
form feed is generated
automatically.
62* Factory default for US (letter)
66* Factory default for EUR (A4)
This function emulates a front panel switch on an IBM printer.
When set to 000, no vertical formatting is done, and no form
feed is generated at bottom of form (BOF).
If MPL is not at top of form (TOF), then form feed (FF) is
performed. The printer ejects paper, and printing is at TOF on
the next page. If the page is empty, FF is suppressed, no paper
ejects, and the printer prints at TOF on the current page. Refer
to the “Form Feed (FF)” section in the “DSC and SCS data stream
commands” chapter for additional information on the FF
command.
Remember When operating in the SCS mode, the form length or MPL can
be downloaded from the host. FSL Y5 function has immediate
effect on the printer, unless form length has been downloaded
from the host, and the value is used when selecting default in
SCS mode.
If the setting stored in RAM for Y5 is 255, the value of Y5
(Maximum Print Lines) will be computed for the user as part of
the automatic configuration logic. The value for Y5 is computed
based on information from Y10 (Portrait/Landscape) and Y11
(Active Tray). The automatic configuration logic computed value
will be take effect if the user has stored a value other than 255
into RAM using FSL X1.
You may disable the Automatic Papersize Configuration logic by
using FSL Y119 (See the FSL Y119 command for more
information.)
Example @Y5, 50@ sets the page length to 50 lines.
XEROX MRP FAMILY COAX COMMAND REFERENCE 3-15