132 • Main Menu XEROX WIDE FORMAT COPY SYSTEM
Sensor Locations on the Synergix Scan System
A: Left Oversize Document
Sensor
D: Register
B: Exit E: Input
C: Right Oversize Document
Sensor
F Discrete Width Sensors (Four on
left and four on right)
c) Observe the Display. When the sensor is activated the icon
O is filled in.
d) Move the sheet of paper fully to the left and right to check
the LEFT and RIGHT sensors.
10. To check the status of the thick document sensor:
a) Raise the Thick Document Lever. When the sensor is
activated the icon
O is filled in.
b) When finished viewing the status of the thick document
sensor, lower the Thick Document Lever.
11. To check the status of HOME sensor.
a) Raise the Document Handler just enough to access the
Calibration Roll drive gear and still be able to see the
Display.
b) Rotate the Calibration Roll one full revolution. The status will
change from NO to YES if the sensor is okay.
D
A
B
C
E
F
F