Xerox FS 5250 IPC All in One Printer User Manual


 
Selected FSL Functions
Xerox FS 5250, User’s Guide
- 73 -
Timeout is specified in FSL Function 100 . This function has the following
syntax (where "%" is the escape character):
%Y100,<timeout>[,user string]%
Timeout: 0 to 255 indicating number of
seconds
Factory default = 20 seconds
User
string:
Optional - string in HEX to be sent to
the printer before transmission of
data, when the printer is selected by
the share unit.
NOTE:
The Timeout string must be a one line command sequence
(see example overleaf).
When function Y100 has been defined for the twinax port, the following will
happen:
When the twinax port takes over the printer after another port has been
used, the defined string will be sent to the printer and the FSL and host
settings will be re-established.
Y100 = 0
If the FSL Y100 timeout string is set to zero, the user string and settings will
be sent the next time the input is active after a time lapse of 20 seconds,
even if no other input has been active.
Y100 > 0
If the FSL Y100 timeout string is set to a value higher than zero, the user
string and settings will only be sent if a share condition has occurred.