Yamaha CRW3200SX Computer Drive User Manual


 
Preparing the CRW3200SX Drive
11
Termination
A terminator prevents the reflection of SCSI signals at the last device of the SCSI
chain. The terminators of the first and last devices of the SCSI chain should be set
to ON. If the CRW3200SX drive is not at the last of the SCSI chain, the
TERMINATOR (SW 4) of the dip switch should be set to OFF.
The TERMINATOR (SW 4) of the dip switch is set at ON by default.
Note
Computer
Extenal SCSI
Device
(unterminated)
CRW3200SX
(terminated)
SCSI card
(terminated)
Termination ON (default) Termination OFF
Set to ON if the CRW3200SX drive
is the last of the SCSI chain
Set to OFF if the CRW3200SX drive
is not the last of the SCSI chain
OFF
ON
OFF
ON