Doc# 27-0023UM Rev 1.0 Issued 09/04
40
SPECIFICATIONS
* Results of Environmental Tests pending
** Unit will power up and is legible at -20°C; backlight life is reduced
Shock MIL-STD-810E (Method 516) 30 g’s
MIL-S-901D (in isolated rack)
Fungus Non-Nutrients/Contaminants
Sand and Dust 5.5 MPH for 25 mins (display bezel only)
Drip MIL-STD-810E (display bezel only)
Reliability
MTBF Display: 20,000 hrs w/ backlight change at 10,000
hrs.
MRRT <30 minutes
Safety UL 1950 (Used as a design guideline)
EMI FCC Class A
Quality/Workmanship IPC/ISO 9001:2000 and applicable section of
MIL-HDBK-454