the charging process per the following table:
UCLI72-4Battery Status Indicators
Amber LED Green LED Battery Status
On Off Charging
On Flashing 80% charged (O.K. to use)
Off On Completely Charged
Flashing Off Fault
Important • A fault condition is caused by a problem with the battery.
The charger may indicate a fault because the battery is too hot or
too cold to charge reliably. Try to charge the battery again when it
returns to the room’s ambient temperature. If the Amber indicator
starts ashing on the second charging attempt, the battery should be
discarded. Always dispose of batteries in a proper manner. Refer to
Appendix E
LI72-4 Charger Cycle Times :
RW 420 RW 220
Battery 80% Charged 2.5 Hrs. 1.25 Hrs..
Battery Fully Charged 5 Hrs.. 2.5 Hrs..
Note • Charge times are for completely discharged batteries.
Partially discharged Battery Packs will take less time than
listed in the chart to reach a fully charged state. Once Battery
Packs have reached 80% of their charge capacity they may be
used, but it is recommended that you allow the batteries to
reach a full charge to maintain maximum battery life.
Note • The UCLI72-4 Quad Charger’s safety features will stop the
battery charging process after six hours regardless of the battery’s
charge state.