Zebra Technologies ZT230 Label Maker User Manual


 
Printer Configuration and Adjustment
Calibrate the Ribbon and Media Sensors
98
P1048261-004 8/22/12
Calibrate the Ribbon and Media Sensors
Use the procedure in this section to calibrate the printer, which adjusts the sensitivity of the
media and ribbon sensors.
For issues that may be resolved by sensor calibration, see Printing Issues on page 129.
For a summary of the options for initiating calibration, see Media and Ribbon Sensor
Calibration on page 87.
To perform sensor calibration, complete these steps:
1. With the printer in the Ready state, initiate media and ribbon calibration in one of these
ways:
Press and hold PAUSE + FEED + CANCEL for 2 seconds.
•Send the ezpl.manual_calibration SGD command to the printer. See the
Zebra Programming Guide for more information about this command.
ZT230 printer only:
a. Navigate to the following menu item on the control panel display. This item is
located under the TOOLS menu and the SENSORS menu. See ZT230 Printer
Control Panel Display on page 17 for information about using the control panel
and accessing the menus.
b. Press RIGHT SELECT to select START.
Important • Follow the calibration procedure exactly as presented. All of the steps must be
performed even if only one of the sensors requires adjustment. You may press and hold
CANCEL at any step in this procedure to cancel the process.
MEDIA/RIBBON CAL
START