Chapter 13 The Phone Screens
User’s Guide
152
The following table describes the labels in this screen.
13.3 Common
Click VOICE > Phone > Common to activate and deactivate immediate dialing.
Figure 66 VOICE > Phone > Common
Table 49 VOICE > Phone > Analog Phone > Advanced
LABEL DESCRIPTION
Voice Volume Control
Speaking
Volume
Enter the loudness that the WiMAX Modem uses for speech that it sends
to the peer device. -14 is the quietest, and 14 is the loudest.
Listening
Volume
Enter the loudness that the WiMAX Modem uses for speech that it
receives from the peer device. -14 is the quietest, and 14 is the loudest.
Echo Cancellation
G.168 Active Select this if you want to eliminate the echo caused by the sound of
your voice reverberating in the telephone receiver while you talk.
Dialing Interval Select
Dialing Interval
Select
Enter the number of seconds the WiMAX Modem should wait after you
stop dialing numbers before it makes the phone call. The value depends
on how quickly you dial phone numbers.
If you select Active Immediate Dial in VOICE > Phone > Common,
you can press the pound key (#) to tell the WiMAX Modem to make the
phone call immediately, regardless of this setting.
VAD Support Select this if the WiMAX Modem should stop transmitting when you are
not speaking. This reduces the bandwidth the WiMAX Modem uses.
Back Click this to return to the Analog Phone screen without saving your
changes.
Apply
Click to save your changes.
Reset Click to restore your previously saved settings.