ZyXEL Communications omni.net LCD+M Network Card User Manual


 
Technical Reference for ZyXEL omni.net series
B-15
All the Following Commands Require a 'AT' Prefix
S Com. bit dec hex Function and description +Def./Ref.
SI=2 2 2 Fax Gruppe 3
3 3 (*) Daten Ober Modem
4 4 Btx Ober Modem
SI=7 0 0 Daten bertragung 64 Kbps (X.75 SLP)
11------
Async. V.110
01------
Extensions of async.
--0-----
(*) Number of data bits: 8
--1-----
Number of data bits: 7
---0----
(*) Number of stop bits: 1
---1----
Number of stop bits: 2
----0---
(*) No parity
----1---
Even parity
11---000
1200 bps
11---011
2400 bps
11---100
4800 bps
11---101
9600 bps
11---110
14400 bps
11---111
(*) 19200 bps
01---000
38400 bps
1010----
Sync. V.110
10100000
1200 bps
10100011
2400 bps
10100100
4800 bps
10100101
9600 bps
10100110
14400 bps
10100111
19200 bps
10101000
48000 bps
10101001
56000 bps
10101010
56000 bps for 56kbit-network