Diagnostics and Troubleshooting 3-49
Table 3-17
Event Messages
continued
Event Type Event Message Action
Processor
Correctable Error
Threshold exceeded
Processor Correctable error Threshold
passed (Slot X, Socket X)
Replace the processor.
Uncorrectable Error Unrecoverable Host Bus Data Parity Error Replace the processor.
Host Bus Error Unrecoverable Host Bus Address Parity
Error
Call the service provider or Compaq
for diagnosis.
PCI Bus Error
PCI Bus Error (Slot X, Bus X, Device X,
Function X)
Power down PCI slot and replace
board
Power Subsystem
Power Supply Failure System Power Supply Failure (Power
Supply X)
Replace power supply
Power Supply Inserted System Power Supply Inserted (Power
Supply X)
None
Power Supply Removed System Power Supply Removed (Power
Supply X)
None
Power Supply
Not Redundant
System Power Supplies Not Redundant Add power supply
System Configuration
Battery Low
Real-Time Clock Battery Failing Replace battery
Power Module Failure A CPU Power Module (System Board,
Socket X)
Replace power module
Power Module Failure A CPU Power Module (Slot X, Socket X) Replace power module
Automatic Server Recovery-2
System Lockup ASR Lockup Detected: Cause Call the service provider or Compaq
for diagnosis.
Operating System
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
System Crash
Abnormal Program Termination: Cause
[NetWare]
Refer to the documentation for the
operating system.
Automatic Operating System Shutdown
Initiated Due to Fan Failure
Automatic Operating System Shutdown
Initiated Due to Overheat Condition
Automatic OS
Shutdown
Fatal Exception (Number X, Cause)
Refer to the documentation for the
operating system.