![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/0b/10b21527-93f0-474c-a880-b7d391b84453/10b21527-93f0-474c-a880-b7d391b84453-bg46.png)
3-16 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1768 - Slot x Drive
Array—Resuming
logical drive
expansion process.
None SMART-2 Controller error No action required. Appears
whenever a controller reset or
power cycle occurs while array
expansion is in progress.
1769 - Slot x Drive
Array—Drive(s)
disabled due to
failure during
expand. Select F1 to
continue with logical
drives disabled.
Select F2 to accept
data loss and to
re-enable logical
drives.
None SMART-2 Controller error Data has been lost while
expanding the array; therefore,
the drives have been
temporarily disabled. Press F2
to accept the data loss and
re-enable the logical drives.
Restore data from backup.
1770 - Slot x drive
array—critical drive
firmware problem
detected—please
upgrade firmware on
the following drive(s)
using Options
ROMPaq (available
from
www.compaq.com):
SCSI port (y) SCSI
ID (x)
(RESUME = F1 or
F2 KEY)
None Firmware update need indicated The indicated drives are running
firmware that is known to cause
intermittent problems. Please
use the Compaq Options
ROMPaq utility to upgrade
firmware on all drives to the
latest revision. Press F1 or F2 to
resume.
1771 - Primary Disk
Port Address
Assignment Conflict
None Internal and external hard drive
controllers are both assigned to
the primary address.
Run the System Configuration
Utility and correct.
1772 - Secondary
Disk Port Address
Assignment Conflict
None Address assignment conflict:
internal and external hard drive
controllers are both assigned to
the secondary address.
Run the System Configuration
Utility and correct.
1773 - Primary Fixed
Disk Port Assignment
Conflict
None Fixed disk drive error Run the System Configuration
Utility and correct.
continued