Diagnostics and Troubleshooting 3-61
Table 3-21
ASR-2 IML Messages
continued
Message Description
NMIPCI Bus Parity Error A parity error was detected on the PCI bus.
NMIExpansion Board Error A board on the expansion bus indicated an error condition, resulting in a
server failure.
NMIExpansion Bus Master
Time-Out
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
NMIExpansion Bus Slave
Time-Out
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
NMIFail-Safe Timer
Expiration
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
Processor Exception The indicated processor exception occurred.
NMIProcessor Parity Error The processor detected a data error, resulting in a server failure.
Server Manager Failure An error occurred with the Server Manager/R.
NMISoftware Generated
Interrupt Detected Error
Software Indicated a system error, resulting in a server failure.
Abnormal Program Termination The operating system has encountered an abnormal situation that has
caused a system failure.
ASR-2 Test Event The System Configuration Utility generated a test alert.
NMIAutomatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer
expiration.
Required System Fan Failure The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
UPS A/C Line Failure Shutdown
or Battery Low
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates whether an auto-shutdown sequence has
been invoked or the battery has been nearly depleted.
ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM.