3-20 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1785 - Drive Array
not Configured
(followed by one of
the following):
None Drive array configuration not
detected
Run Compaq
Array
Configuration
Utility
Run the Compaq Array
Configuration Utility.
No drives
detected
Turn off system and check SCSI
cable connections to make sure
drives are attached properly.
Drive positions
cannot be
changedRun
Drive Array
Advanced
Diagnostics if
previous
positions are
unknown. Then
turn system
power OFF and
move drives to
their original
positions.
Run Drive Array Advanced
Diagnostics if previous positions
are unknown. Then turn system
power off and move drives to
their original positions.
Configuration
information
indicates drive
positions beyond
the capability of
this controller.
This may be due
to drive
movement from
a controller that
supports more
drives than the
current
controller.
To avoid data loss, turn system
power off and reattach drives to
the original controller.
Configuration
information
indicates drives
were configured
on a controller
with newer
firmware.
To avoid data loss, reattach
drives to original controller or
upgrade the controller firmware
to the version on the original
controller using Option ROMPaq.
Press F1 key to resume.