3-24 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1794 - Drive Array—
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
None This is a warning that the battery
charge is below 75%.
Posted-writes are disabled.
Replace the Array Accelerator
board if batteries do not
recharge within 36 power-on
hours.
1795 - Drive Array—
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
None This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory.
The data stored in the Array
Accelerator does not correspond
to this drive array.
Match the Array Accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the Array
Accelerator.
1796 - Drive Array—
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
None Array Accelerator is defective or
has been removed.
1. Check that the Array
Accelerator is properly
seated.
2. Run System Configuration
Utility to reconfigure the
Compaq IDA-2 without the
Array Accelerator.
continued