3-12 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1611 - I/O Fan
(Fan X) failure
detected
2S I/O fan has failed Replace the failed fan.
1611 - CPU Fan
(Fan X) failure
detected
2S CPU fan has failed Replace the failed fan.
1612 - Primary
power supply failure
2S Primary power supply has failed Replace power supply as soon
as possible.
1613 - Low System
Battery
None Real time clock system battery is
running low on power
Run Diagnostics. Replace failed
assembly as indicated.
1615 - Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X
None A power supply has failed. Replace or check specified
power supply.
1617 - Fan controller
not responding
2S Fan controller failure Check and replace failed
controller assembly.
1617 - I/O Fan
controller not
responding
2S I/O fan controller failure Check and replace failed
controller assembly.
1617 - CPU Fan
controller not
responding
2S CPU fan controller failure Check and replace failed
controller assembly.
1620 - Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None SCSI bus failure Run Diagnostics. Replace failed
assembly as indicated.
1621 - Current SCSI
bus cable
configuration is not
recommended
None Improper SCSI bus cabling Check documentation for proper
SCSI bus cabling.
1622 - Internal SCSI
Jumper Board Not
Installed
None The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
continued