A SERVICE OF

logo

Diagnostics and Troubleshooting 3-23
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1789 - Slot x Drive
array SCSI physical
drive(s) Not
Responding, Check
cables or replace the
following drives: SCSI
port (x): SCSI ID (x)
Select F1 to
continuedrive
array will remain
disabled.
Select F2 to fail
drive(s) that are not
respondingInterim
Recovery Mode will
be enabled if
configured for fault
tolerance.
None Cable or hard drive failure 1. Check the cable
connections.
2. If cables are connected,
replace the drive.
3. If you do not want to
replace the drive now,
press F2.
1790 -
Disk 0 Configuration
Error
None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1791 - Disk 1 Error None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1792 - Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
None This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory.
Power was then restored
within 8 to 10 days, and the data
in the Array Accelerator was
flushed to the drive array.
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid data
remaining in the Array
Accelerator.
1793 - Drive Array
Array Accelerator
Battery Depleted
Data Lost
(Error message 1794
also displays.)
None This indicates that while the
system was in use, power was
interrupted while data was in the
Array Accelerator memory. Array
Accelerator batteries failed. Data
in the Array Accelerator has been
lost.
Power was not restored within
8 to 10 days. Perform orderly
system shutdowns to avoid data
remaining in the Array
Accelerator.
continued