HCD-E1 Installation & Operation Manual Chapter 4 - Control from the Supervisory Port
11/01/00 19:23 HCD-E1 Command Set Description 4-31
DSP ALM REM
Purpose
Display the contents of the alarm buffer of the appliance located at the
remote end of the HDSL link. This buffer can contain up to 100 alarms.
Syntax
DSP ALM REM[Option]
Use
To display the complete contents of the remote buffer, type:
DSP ALM REM<CR>
*To display the complete buffer contents and then clear the ON-type
alarms, type:
DSP ALM REM/C<CR>
*To display the complete buffer and then clear all the stored alarms,
type:
DSP ALM REM/CA<CR>
*See the description of CLR ALM command earlier in this chapter for
explanation of what the “clear” action means.
The format of the remote alarm buffer display is similar to the format for the
local alarm buffer, described in the DSP ALM section above.
DSP BERT CH
Purpose
Display the results of an on-going bit error ratio measurement on the desired
channel.
When monitoring the BER results, you may also start and stop error
injection, and restart the error count by clearing the accumulated error
results. Note that monitoring is not possible when using Telnet.
The error injection rate is defined by means of the DEF BERT command (see
earlier in this chapter).
Syntax
DSP BERT CH X
Use
To display the current results of a BER test on channel 1, type:
DSP BERT CH 1<CR>
To display the current results of a BER test on channel 2, type:
DSP BERT CH 2<CR>
Note
These commands are valid only when the BERT test (LOOP BERT) is active on
the specified channel, otherwise HCD-E1 displays ERROR 26.