A SERVICE OF

logo

HCD-E1 Installation & Operation Manual Chapter 4 - Control from the Supervisory Port
11/01/00 19:23 HCD-E1 Command Set Description 4-43
The fields included in the status information display are listed below:
LINE LOOP
Displays the state of the local line loop on the
corresponding HDSL line.
NO Local line loop is not activated
YES Local line loop is activated
LINE ALARMS
Displays the state of the line alarms on the corresponding
HDSL line:
SYNC LOSS ON indicates loss of synchronization on the
corresponding HDSL line.
OFF indicates normal operation.
SIGNAL LOSS ON indicates loss of input signal on the
corresponding HDSL line.
OFF indicates normal operation.
HRPT LOOP
Displays the state of the H-RPT loop towards the unit
configured as central (appears only if H-RPT is present on
the HDSL line).
NO H-RPT loop is not activated
YES H-RPT loop is activated
DSP ST SL
Purpose
Display status information on the local E1 sublink, and optionally clear the
BPV counters (applicable only when the CRC-4 function is disabled).
Syntax
DSP ST SL [Option]
Use
To display the current status information for the E1 sublink, type:
DSP ST SL
To display the status information, and then clear the BPV counters, type:
DSP ST SL /C<CR>
HCD-E1 performs the command and displays the date and time followed by
the HCD-E1 prompt.
To monitor continuously the status information, type:
DSP ST SL /R<CR>
The display will be automatically updated. To stop the monitoring,
press CTRL+C.