3Com WX1200 Switch User Manual


 
182 CHAPTER 7: IP SERVICES COMMANDS
Syntaxset snmp notify target target-num
ip-addr[:udp-port-number]
usm inform user username
snmp-engine-id {ip | hex hex-string}
[profile profile-name]
[security {unsecured | authenticated | encrypted}]
[retries num]
[timeout num]
target-num — ID for the target. This ID is local to the WX switch and
does not need to correspond to a value on the target itself. You can
specify a number from 1 to 10.
ip-addr[:udp-port-number] — IP address of the server. You also
can specify the UDP port number to send notifications to.
username — USM username. This option is applicable only when the
SNMP version is usm. If the user will send informs rather than traps,
you also must specify the snmp-engine-id of the target.
snmp-engine-id SNMP engine ID of the target. Specify ip if the
{ip | hex hex-string} target’s SNMP engine ID is based on its
IP address. If the target’s SNMP engine ID is a
hexadecimal value, use hex hex-string to
specify the value.
profile profile-name — Notification profile this SNMP user will use
to specify the notification types to send or drop.
security Specifies the security level, and is applicable only
{unsecured | when the SNMP version is usm:
authenticated | - unsecured — Message exchanges are not
encrypted} authenticated, nor are they encrypted. This is
the default.
-
authenticated — Message exchanges are
authenticated, but are not encrypted.
-
encrypted — Message exchanges are
authenticated and encrypted.
retries num — Specifies the number of times the MSS SNMP engine
will resend a notification that has not been acknowledged by the
target. You can specify from 0 to 3 retries.
timeout num — Specifies the number of seconds MSS waits for
acknowledgement of a notification. You can specify from 1 to 5 seconds.