4-2. Projector Control Panel
Indicator Lamps
The projector control panel (Figure 4-1) has several indicator lamps that illuminate to indicate normal
operation and when alarm conditions have been detected. Refer to the chart below for details.
Normal Operation Indicator Lamps
LED Status of the Unit
Main Power: ON STANDBY/ON: ON
Lamp: OFF
STANDBY/ON: ON
Lamp: ON
Receiving Remote
Control Signal
POWER Amber GREEN GREEN
REMOTE OFF OFF OFF Blinking GREEN
CHANGE LAMP OFF OFF OFF
COVER OFF OFF OFF
FAN OFF OFF OFF
TEMP OFF OFF OFF
LAMP OFF Blinking GREEN GREEN
Alarm Indicator Lamps
LED Status of the Unit
Lamp Failure Temperature
Failure
Right Panel
Open
Lamp Life Over
(>1000 hours)
Fan Failure
POWER Amber Amber Amber GREEN Amber
REMOTE
CHANGE LAMP RED
COVER RED
FAN RED
TEMP RED
LAMP RED
Special/Reset Buttons
Press the SPECIAL button (Figure 4-1) to view the
firmware revision level and the current input data
(RGB or Video) for the projector. The TEST
SCREEN (Figure 4-2) will display. If no input is
detected, the message “NO INPUT” will display.
RGB1
TEST SCREEN
FIRMW
ARE REV
#1001
1A
SVGA56
H xx.x kHz
V xx.x Hz
VIDEO1
TEST SCREEN
FIRMW
ARE REV
#1001
1A
NTSC
Figure 4-2. Test Screens
Press the RESET button (Figure 4-1) to reset all
projector settings to the factory default. Press the
down arrow to change to YES (Figure 4-3) and press
the SELECT button. Press the SELECT button again
to activate the settings and the message “RESET
COMPLETE will display.
RESET
ALL SETTINGS T
O
F
ACTOR
Y DEF
AULT
NO
YES
Figure 4-3. Reset Screen