Adaptec ANA-5910 Network Card User Manual


 
B-11
Windows NT Specific Error Messages and Diagnostics
Diagnostics
The hardware diagnostic utility
aatmdiag.exe
is
a command-line
interface that can be used to validate that the adapter is functioning
properly. Only three commands are needed to completely test the
adapter. These are the selftest, extended SAR memory tests, and the
external ATM tests (using an external loopback cable).
W5350 received packet is not ip or arp
A packet was received that is not IP or
ARP. Check the ATM address and
selector assignment to see if
atmo.sys
or
aarp.sys
could be receiving packets
for another application , for example,
LAN Emulation, by mistake.
W5401 pvc bind failed
There is a mismatch between the PVCs
configured for Classical IP
and for
atmo.sys
. Make sure that the VPI/VCI
numbers in the
acip.db
and
base.db
files are consistent.
W5410 SETUP received -
invalid called atm address
W5411 SETUP received -
cannot find matching subnet
W5412 SETUP received -
invalid calling atm address
W5413 SETUP received -
invalid aal5 parameters
W5414 SETUP received -
invalid blli
W5415 SETUP received -
invalid vpi / vci
W5420 CONNECT received -
invalid aal5 parameters
W5421 CONNECT received -
invalid vpi / vci
W5430 CALL PROCEEDING
received - invalid vpi / vci
An invalid signalling message for
Classical IP was received. Check the
configuration of other stations for
consistency. All IP stations must use
the same MTU size—no MTU
negotiation is performed. Receiving a
different value to that configured will
result in the
invalid aal5 parameters
error. Also check the ATM address and
selector assignment.
Driver Console Error Message Description