Adaptec SAS/SATA/SCSI RAID Controllers Network Card User Manual


 
Chapter 5: Installing the Controller and Disk Drives 36
Next Steps
If you are installing the controller driver and an operating system onto a bootable array,
continue with Creating a Bootable Array on page 37.
If you are completing a standard installation onto an existing operating system, continue with
Installing the Driver on an Existing Operating System on page 49.
Monitoring Disk Drives with Adaptec Storage Manager
Adaptec Storage Manager allows you to monitor the status of your SAS, SATA, or SCSI disk
drives. Within Adaptec Storage Manager, you can select a disk drive object and a command will
be sent to the backplane (for internal disk drives) or enclosure (for external disk drives). The
LED associated with that disk drive will flash. The following table describes the LED flash
states. For more information refer to the Adaptec Storage Manager Help.
Controller Device State Slot State LED Flash State
Failed Device is faulty On
Rebuilding Device is rebuilding Slow flash
Blink Identify the device Fast flash
Other No error Off