Drive Configuration
43
1
No Term Power
Disable Active Termination
2
No Term Power
Enable Active Termination
3
Term Power
Disable Active Termination
4
Term Power
Enable Active Termination
Figure 14. TRM PWR/TRM ENB Jumper Positions
If . . . And . . . Response . . .
Another device is
providing terminator power
The DS9000 Series
is
not
at the end of the SCSI bus
chain
Connect jumpers as in Figure 12.
Another device is
providing terminator power
The DS9000 Series
is
at the
end of the SCSI bus chain
Connect jumpers as in Figure 12.
No other device on the
SCSI bus is providing
terminator power
The DS9000 Series
is
not
at the end of the SCSI bus
chain
Connect jumpers as in Figure 12.
No other device on the
SCSI bus is providing
terminator power
The DS9000 Series
is
at the
end of the SCSI bus chain
Connect jumpers as in Figure 12.
DLT7000/DLT8000 Drives
The DLT7000/DLT8000 drives can be configured to supply terminator power, by placing jumpers across specific
pins on the TRM PWR connector (see Figure 15 for the location of the TRM PWR connector, and Figure 16 for
location of pin pair 3/4).