NetVanta T1/FT1 NEBS NIM (P/N 1200862L2#NEBS)
The NetVanta T1/FT1 NEBS NIM (shown in Figure 18) provides a T1 (full or fractional) WAN interface
for the NetVanta 3205 DC. The T1 NEBS NIM provides a full T1 or fractional T1 network interface. See
Table A-7 on page 87 for the WAN-T1 connector pinouts.
Figure 18. NetVanta T1/FT1 NEBS NIM
The 1200862L2#NEBS is intended for use only with the Netvanta 3205 DC (P/N
1202980L1).
WAN-T1
Features and Specifications
Operating Modes
Frame Relay, multilink Frame Relay
PPP, MLPPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples
of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
•Network
•Internal
Diagnostics
Test Pattern Generation and Detection:
QRSS, 511, 2
15
- 1, 2
20
- 1, all ones,
all zeros
Network loopbacks (local and remote);
responds to inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
NEBS Level 3
•GR-63-CORE
GR-1089-CORE
UL/CUL 60950-1
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D