ADTRAN 1202880E1 Network Router User Manual


 
Option Modules NetVanta 3200/3300/3400 Series
52 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB
NetVanta Serial NIM (P/N 1200866E1)
The NetVanta Serial NIM (shown in Figure 23) can be configured by the user as a V.35, X.21 (V.11), or
EIA 530 interface. This module supports rates up to a maximum of 10 Mbps. An additional V.35
(ADTRAN P/N 1200873L1), X.21 (ADTRAN P/N 1200874L1), or EIA 530 (ADTRAN P/N 1200883L1)
cable is required (see Caution below). See Table A-14 on page 90 for the serial connector pinouts, and
Table A-15 on page 91 for the DBU connector pinouts. An optional DIM is required for dial backup
applications.
Figure 23. NetVanta Serial NIM
Cable length for the Serial NIM should not exceed 25 feet.
SERIAL DBU
Features and Specifications
Operating Mode
DTE only
Serial Interface
Supported Standards: ISO 4903 (X.21),
CCITT V.35 Synchronous (V.35),
EIA 530 Synchronous
Provides V.35, X.21 (V.11), or EIA 530
electrical interface
Connector: 26-pin smart serial (DTE)
Compliance
EMC - see Electromagnetic
Compatibility (EMC) Table on page 6.
ETSI TBR1
ETSI TBR2
EN 60950-1
IEC 60950-1
UL/CUL 60950-1
AS/NZS 60950-1
RoHS compliant (1200866E1 only)
(Telecommunications exemption)
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D