ADTRAN 1202880E1 Network Router User Manual


 
NetVanta 3200/3300/3400 Series Option Modules
61200860L1-34AB Copyright © 2012 ADTRAN, Inc. 49
NetVanta Dual T1 NIM (P/N 1200872L1/1202872L1)
The NetVanta Dual T1 NIM (shown in Figure 20) provides two WAN T1 interfaces for the NetVanta 3000
Series. The module provides up to 2.048 Mbps on each network interface. See Table A-7 on page 87 for the
pinouts. See Table A-15 on page 91 for the DBU connector pinouts. An optional DIM is required for dial
backup applications.
Figure 20. NetVanta Dual T1 NIM
The 1200872L1 Dual T1 module supports the analog modem (1200864L1), ISDN BRI
(1200865L1), and ISDN S/T (1200875L1) DIMs for dial backup applications. The
1202872L1 Dual T1 module supports only the analog modem (1200864L1) DIM for dial
backup applications.
WAN T1/1 DBUWAN T1/2
Features and Specifications
Operating Modes
Frame Relay, multilink Frame Relay
PPP, MLPPP
HDLC
T1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized
(multiples of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
•Network
•Internal
Through
Diagnostics
Test Pattern Generation and Detection:
QRSS, 511, 2
15
- 1, 2
20
- 1, all ones,
all zeros
Network loopbacks (local and remote);
responds to both inband and FDL loop
codes
Alarm generation detection
Network performance data (15 minutes
and 24 hours)
Compliance
EMC - see Electromagnetic
Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950-1
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D