Agilent Technologies E1300B Computer Hardware User Manual


 
Scanning Voltmeter Menu
Menu Levels and Content
Level 1 Level 2 Level 3 Level 4 User Entry Command(s) Used Description
(continued from previous page)
UNSTRN channel list † MEAS:STR:UNST? < channel_list> Measure bridge unstrained
DIAG COMPRES channel list † MEAS:STR:QCOM? < channel_list> Compression shunt diagnostic
TENSION channel list † MEAS:STR:QTEN? < channel_list> Tension shunt diagnostic
CARD TYPE? card number ‡ SYST:CTYP? <card_number> Displays module ID information
DESCR? card number ‡ SYST:CDES? < card_number> Displays module description
TEST * TST? Runs self-test, displays results ( + 0= pass; any other
number= fail)
† Channel lists are of the form “ccnn” (single channel), “ccnn,ccnn” (two or more channels) or “ccnn:ccnn” (range of channels); where “cc” is the card number and “nn” is the channel
number. For example, to access channel 2 on card number 1 specify 102.
‡ The card number identifies a module within the Switchbox. The switch module with the lowest logical address is always card number 01. The switch module with the next
successive logical address is card number 02 and so on.
Using the Display Terminal Interface 2-19