2.3. Com pres sed air supp ly
For actuating the piston in the SKW
a compressed air supply
connection (1/4 inch) is required.
Check compressed air piping for
correct installation and assembly.
Check fittings, length and quality of
the hose connections for
agreement with requirements.
The operating pressure of the SKW
is 5-6 bar (72.52-87.02 PSI)
(system overpressure).
Check the compressed air supplied
by the plant’s supply network.
Adjust compressed air pressure to
5-6 bar(72.52-87.02 PSI) (system
overpressure).
Compressed air must be dewatered and oiled.
Install a maintenance unit (pressure reducer with water separator and oiler) if
required.
Connect the SKW to the plant’s supply network by means of a hose.
L
Depressurize compressed air supply lines which must be
opened.
F
Compressed air must be dewatered and oiled.
Adjust pressure to a max. value of 6 bar (87.02 PSI)
(system overpressure).
046-3MS
SKW
In stal la ti on in struc tions 20
Maintenance unit