Altinex MT110-100/102 Switch User Manual


 
MULTITASKER
400-0132-005
12
The matrix I/O connections are also read left to
right representing outputs 1-8 and the input to
which each is connected. The first two digits
show the input number to which Output 1 is
connected. The third and forth digits are for
Output 2 and so on.
The matrix configuration shows the current
configuration of the matrix, either 16x8, 8x4 or
4x2.
The output volume levels are read the same as
the matrix connections. The first two digits are
the volume level for Output 1, the third and forth
are for Output 2 and so on.
The mute status is either a ‘1’ or a ‘0’. A ‘1’
indicates the card outputs are muted. A ‘0’
means the outputs are on.
6. [STA1]
This command enables automatic feedback
from the front panel. The command affects any
card with auto-feedback capability, not just the
MT110-102. The default at power on or reset is
STA0, off. For more details, see the [?Cn]
command definition.
Command Format [STA1] = On
Feedback Prefix Definitions:
MT Card Model Number
VR Firmware Revision
ON Output On/Off Status
MA Matrix Connections
MX Matrix Configuration
VO Output Volume
MU Mute On/Off
Example 1:
Command = [I2O*C4]
Feedback = (MA020202…C04)
MA = Matrix Connections
0202.. = Input 2 to Output 1
Input 2 to Output 2
etc…
C04 = Card/Slot number
7. [STA0]
This command disables automatic feedback
from the card and front panel. The command
affects any card with auto-feedback capability,
not just the MT110-102. The default at power on
or reset is STA0, OFF.
Command Format [STA0]
8. [ON]
This command will enable an output of a single
card, or a group of cards.
SINGLE CARD OPERATION
Command Format: [ONmCnUi]
m = Output No. (m = # from 1 to 8)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
There is an MT110-102 card in slot 5. All of the
outputs on the card are off.
1) [ON1C5]: Turns on only Output 1 of the
MT110-102 card.
2) [ONC5]: Turns on all outputs of the
MT110-102 card.
GROUP OPERATION
This command enables output ‘m’ for each card
in group ‘k’ of unit ‘I’.
Command Format: [ONmGkUi]
m = Output number (m = # from 1-8)
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
[ON1G1]: Turns ON Output 1 for each card in
Group 1. See the GROUP commands for a
detailed explanation.