PATH OPERATION
The path for outputs on the same or multiple
cards may be preloaded. This will set the path
for the output, but it is not active until the switch
command, [SW], is executed. Commands
ending in ‘P’ are not executed immediately.
Command Format: [ONmCnUiP]
m = Output No. (m = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
P = Path
Example:
An MT110-102 card is in slot 4 and another in
slot 8. Enable Output 1 of C4 and Output 3 of
C8 simultaneously by sending the following:
[ON1C4P]
[ON3C8P]
[SW]
If "F" is included, use the [ONmCnPF] command
or the [ONmCnFP] command.
FEEDBACK OPERATION
After processing a command, an “OK” or
“[ERR001]” will be returned as feedback if ‘F’ is
included at the end of a command string.
Command Format: [ON…..F]
Example:
[ON1C2F]: if path is not set
[ON1C2PF]: if path is set
9. [OFF]
This command disables one or all outputs of a
single card or a group of cards.
SINGLE CARD OPERATION
Command Format: [OFFmCnUi]
m = Output No. (m = # from 1 to 8)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Card 5 has Output 1 on. The following
commands may be used to turn off the input.
1) [OFF1C5]: Turns off only Output 1.
2) [OFFC5]: Turns off all outputs.
GROUP OPERATION
This command disables output ‘m’ for each card
in group ‘k’ of unit ‘i’.
Command Format: [OFFmGkUi]
m = Output No. (m = # from 1-8, * for all)
Gk = Group ID (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
1. [OFF1G1]: Turns off Output 1 for each card
in Group 1.
2. [OFFG1]: Turns off all outputs for each
card in Group 1.
PATH OPERATION
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card may be
preloaded.
Command Format: [OFFmCnUiP]
m = Output (m = # from 1 to 8, * for all)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
P = Path
Example:
There are two MT110-102 cards in slots 4 and
8. Disable Output 1 of card 4 and Output 3 of
card 8 simultaneously using the following
commands:
[OFF1C4P]
[OFF3C8P]
[SW]