AMCC 9500S Computer Accessories User Manual


 
Chapter 2. CLI Syntax Reference
38 3ware Serial ATA RAID Controller CLI Guide
/c
x
show allunitstatus
This command presents a count of total and Not Optimal units managed by
the specified controller /cx. For more about the meaning of Not Optimal, see
“Shell Object Commands” on page 23.
Example:
//localhost> /c0 show allunitstatus
/c0 Total Optimal Units = 2
/c0 Not Optimal Units = 0
/c
x
show drivestatus
This command reports a list of drives and their port assignment, status, the
unit with which they are associated, their size in gigabytes and blocks, and the
serial number assigned by the drive manufacturer. (Definitions of the drive
statuses are available in the 3ware Serial ATA RAID Controller User Guide.)
Example:
//localhost> /c0 show drivestatus
Port Status Unit Size Blocks Serial
--------------------------------------------------------------
p0 OK u0 149.05 GB 312581808 3JS0TF14
p1 OK u0 149.05 GB 312581808 3JS0TETZ
p2 OK u1 149.05 GB 312581808 3JS0VG85
p3 OK u1 149.05 GB 312581808 3JS0VGCY
p4 OK u1 149.05 GB 312581808 3JS0VGGQ
p5 OK u2 149.05 GB 312581808 3JS0VH1P
p6 OK - 149.05 GB 312581808 3JS0TF0P
p7 OK - 149.05 GB 312581808 3JS0VF43
p8 OK - 149.05 GB 312581808 3JS0VG8D
p9 NOT-PRESENT - - - -
p10 NOT-PRESENT - - - -
p11 NOT-PRESENT - - - -