Example of migrate output
The following is an example of how migrating units will be displayed. In this
example, the report indicates that
/c0/u3 is a migrating unit with 39%
completion. The report also indicate that Source Unit
su0 is of type RAID-1
and Destination Unit
du0 is of type RAID-10.
3ware CLI> /c0 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
---------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 596.004 ON OFF
u2 SPARE OK - - - 149.042 - OFF
u3 Migrator MIGRATING - 39 - 149.001 ON OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 149.05 GB 312581808 WD-WCANM1771318
p1 OK u0 149.05 GB 312581808 WD-WCANM1757592
p2 OK u0 149.05 GB 312581808 WD-WCANM1782201
p3 OK u0 149.05 GB 312581808 WD-WCANM1753998
p4 OK u2 149.05 GB 312581808 WD-WCANM1766952
p5 OK u3 149.05 GB 312581808 WD-WCANM1882472
p6 OK u0 149.05 GB 312581808 WD-WCANM1883862
p7 OK u3 149.05 GB 312581808 WD-WCANM1778008
p8 OK - 149.05 GB 312581808 WD-WCANM1770998
p9 NOT-PRESENT - - - -
p10 OK u3 149.05 GB 312581808 WD-WCANM1869003
p11 OK u3 149.05 GB 312581808 WD-WCANM1762464
3ware CLI> /c0/u0 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
------------------------------------------------------------------------
u3 Migrator MIGRATING - 39 - - -
su3 RAID-1 OK - - - - 149.001
su3-0 DISK OK - - p5 - 149.001
su3-1 DISK OK - - p7 - 149.001
su3/v0 Volume - - - - - 149.001
du3 RAID-10 OK - - - 16K 298.002
du3-0 RAID-1 OK - - - - -
du3-0-0 DISK OK - - p5 - 149.001
du3-0-1 DISK OK - - p7 - 149.001
du3-1 RAID-1 OK - - - - -
du3-1-0 DISK OK - - p10 - 149.001
du3-1-1 DISK OK - - p11 - 149.001
du3/v0 Volume - - - - - 149.001