AMCC 9590SE-4ME Computer Hardware User Manual


 
Shell Object Commands
www.3ware.com 21
(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5,
BBU of '-' (Not Applicable). Not Optimal refers to any state except OK and
VERIFYING. Other states include VERIFY-PAUSED, INITIALIZING, INIT-
PAUSED, REBUILDING, REBUILD-PAUSED, DEGRADED,
MIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and
UNKNOWN. RRate also applies to initializing, migrating, and recovery
background tasks. (Definitions of the unit statuses are available in the 3ware
Serial ATA RAID Controller User Guide.)
For a system with an enclosure unit such as the 3ware Sidecar that includes
support for an EPCT (Enclosure Port Configuration Table), applicable
firmware and software, and an appropriate controller (9550SX, 9590SE, or
9650SE), a global view of the environment also includes summary
information about detected enclosures.
Example:
Typical output of the Show command for a system with an enclosure looks
like the following:
//localhost> show
Ctl Model Ports Drives Units NotOpt RRate VRate BBU
---------------------------------------------------------------------------
c0 9590SE-4ME 4 2 1 0 4 4 -
Encl Slots Drives Fans TSUnits Ctls
---------------------------------------------------
e0 4 2 1 1 1
The output above shows the enclosure summary information with the name of
the enclosure, the protocol used, the number of drive slots, the number of
drives, the number of fans, the number of temperature sensors, and the
number of controllers that are associated with the enclosure.
show ver
This command will show the CLI and API version.
Example:
//localhost> show ver
CLI Version = 2.00.00.0xx
API Version = 2.00.00.0xx
where xx is the actual version. See the Release Notes for details.